是否提供加工定制:否 | 品牌:日本菊水 | 型号:KES4021A/4022A |
测量范围:符合IEC61000-4-4 Ed2.0:2008标准要求 | 测量精度:1-99999次,无限 | 电源:100VAC-240V 50/60Hz |
用途:模拟带电操作人员直接向电气电子设备仪器放电,或间接放电的抗扰性测试 |
KIKUSUI静电放电模拟仪KES4021A ,菊水静电放电模拟仪KES4021A,进口静电放电模拟仪KES4021A
详细st1:*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:普通表格; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} table.MsoTableGrid {mso-style-name:网格型; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; border:solid windowtext 1.0pt; mso-border-alt:solid windowtext .5pt; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-border-insideh:.5pt solid windowtext; mso-border-insidev:.5pt solid windowtext; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; text-align:justify; text-justify:inter-ideograph; mso-pagination:none; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;}
静电放电模拟仪KES4021A
概要:静电放电是人们生活中经常发生的一种现象。当这种放电引发的电弧电流和电磁波进入电气电子设备仪器的线路网中时,则有导致错误操作和损坏电子元件的危险。为此,很早开始,人们就围绕着IEC标准等展开了研讨,将涉及静电放电的抗扰性测试方法和规定,制定成规范化的标准。同时,最近除对民生用设备仪器提出要求外,面向车载电子仪器提出的要求也在不断地升级。本仪器可用于模拟带电操作人员直接向电气电子设备仪器放电,或间接放电的抗扰性测试。
特点:
1.接口RS-232C
2.符合EN/IEC61000-4-2标准要求的静电放电模拟仪
3.最大测试电压∶可在±30kV的宽松条件下实施测试
4.提高了波形品位(可输出扰动较少的波形)
5.采用了注重操作性的新颖面板设计
6.可适用ISO10605标准/各类静电标准
7.符合EN/IEC61000-4-2标准要求的静电放电模拟仪,最大测试电压∶可在±30kV的宽松条件下实施测试,提高了波形品位(可输出扰动较少的波形),采用了注重操作性的新颖面板设计,可适用ISO10605标准/各类静电标准(KES4022A)
型号 | 规格 |
KES4022A-NEW | 符合EN/IEC61000-4-2标准要求的静电放电模拟仪,最大测试电压∶可在±30kV的宽松条件下实施测试,提高了波形品位(可输出扰动较少的波形),采用了注重操作性的新颖面板设计,可适用ISO10605标准/各类静电标准。通过应用软件(标准附加品),在电脑上进行工作模式编辑(主体也可进行设定) |
KES4021A-NEW | 符合EN/IEC61000-4-2标准要求的静电放电模拟仪,最大测试电压∶可在±30kV的宽松条件下实施测试,提高了波形品位(可输出扰动较少的波形),采用了注重操作性的新颖面板设计,可适用ISO10605标准/各类静电标准 |
选购件(关联产品):
1.CR31-KES-NEW
[KES402XA用选购件]适用适用IEC61000-4-2标准的CR组件(150 pF/330Ω)
2.AT31-KES-NEW
[KES402XA用选购件]大气放电尖端(330Ω)
3.CT31-KES-NEW
[KES402XA用选购件]接触式放电尖端(330Ω)
4.CR32-KES-NEW
[KES402XA用选购件] CR组件(330pF/330Ω)for ISO10605 Ed.2.0
5.CR33-KES-NEW
[KES402XA用选购件] CR组件(150pF/2kΩ)for ISO10605 Ed.2.0
6.CR34-KES-NEW
[KES402XA用选购件] CR组件(330pF/2kΩ)for ISO10605 Ed.2.0
7.AT32-KES-NEW
[KES402XA用选购件]大气放电尖端(Resistance value 2kΩ)
8.CT32-KES-NEW
[KES402XA用选购件]接触式放电尖端(Resistance value 2kΩ)
9.ST31-KES-NEW
[KES402XA用选购件]球体大气放电尖端(Resistance value 330Ω)
10.ST32-KES-NEW
[KES402XA用选购件]球体大气放电尖端(Resistance value 2kΩ)
11.GP21-KES
[KES4021用选购件]标准接地接线板
12.GS21-KES
[KES4021用选购件]放电枪支撑架
13.EC21-KES
[KES4021用选购件] C组件 (150pF)
14.EC22-KES
[KES4021用选购件] C组件 (100pF)
15.EC23-KES
[KES4021用选购件] C组件 (200pF)
16.EC24-KES
[KES4021用选购件] C组件 (250pF)
17.EC25-KES
[KES4021用选购件] C组件 (300pF)
18.EC26-KES
[KES4021用选购件] C组件 (330pF)
19.EC27-KES
[KES4021用选购件] C组件 (400pF)
20.EC28-KES
[KES4021用选购件] C组件 (500pF)
21.DR21-KES
[KES4021用选购件]放电电阻器 (330Ω)
22.DR22-KES
[KES4021用选购件]放电电阻器 (100Ω)
23.DR23-KES
[KES4021用选购件]放电电阻器 (150Ω)
24.DR24-KES
[KES4021用选购件]放电电阻器 (200Ω)
25.DR25-KES
[KES4021用选购件]放电电阻器 (300Ω)
26.DR26-KES
[KES4021用选购件]放电电阻器 (400Ω)
27.DR27-KES
[KES4021用选购件]放电电阻器 (500Ω)
28.DR28-KES
[KES4021用选购件]放电电阻器 (1kΩ)
29.DR29-KES
[KES4021用选购件]放电电阻器 (1.5kΩ)
30.DR30-KES
[KES4021用选购件]放电电阻器 (2kΩ)
31.DR31-KES
[KES4021用选购件]放电电阻器 (5kΩ)
32.DR32-KES
[KES4021用选购件]放电电阻器 (10kΩ)
33.DR33-KES
[KES4021用选购件]放电电阻器 (10Ω)
34.TT21-KES
[KES4021用选购件]测试用电缆
35.ZC21-KES
[KES4021用选购件]水平连接板
36.IS21-KES
[KES4021用选购件]绝缘胶带
37.VC21-KES
[KES4021用选购件]垂直连接板(台式机型)
38.CL21-KES
[KES4021用选购件]电阻电缆
39.IP21-KES
[KES4021用选购件]绝缘台
40.VC22-KES
[KES4021用选购件]垂直连接板(卧式)
41.CS21-KES
[KES4021用选购件]电流检测转换仪
42.FC21-KES
[KES4021用选购件]法拉第柜